*********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v2.1c UK Issue Build Date/Time : Thu May 16 11:39:48.12 2002 (c) DrayTek Corp. *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k0021c.all --- Lastest released firmware \Firmware\v2k0021c.rst --- Lastest released firmware with default settings << Tools >>> \Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c firmware or later. \Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000 \Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95 \Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98 Hint for upgrading Firmware: 1. The file v2k0021c.all or .all file must be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode (press any key from terminal whilst booting) 2. If you don't care about the current settings in your Vigor2000 or you want to reset the router, you could upgrade v2k0021c.rst to resotore settings to be default values. We recommended you upgrade this file if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. The bin & web files must be obtained from your dealer. Support Models: Vigor2000 Release Notes: [NAT] 1. Improve NAT to support some specific applications: ICQ2000, MSN Messenger, NetMeeting. Don't need to set DMZ host any more and can support multi-users in the local LAN. 2. Support MSN Messenger v4.6 ( v3.6 also can work properly ). 3. Spport ICQ2001b and ICQ2000b. 4. Improved PPTP server pass-through problem. 5. Portmap checking improvement. Fixed the problem that sometimes router becomes very slow after establishing a lot of sessions. 6. Improved the problem that port 56415 could be found from Wan port. 7. Improved the problem that FXP ( a FTP application ) can not work properly. [ISDN] 1. Modified ISDN number input checking to allow charaters '#' and '*' could be typed in all ISDN dial number input fields on WUI. [Syslog] 1. Web Configurator: add a "Syslog Setting" in "Diagnostic Tools" for Syslog setting. Please click "Enable" and enter the host's IP in "Syslog output IP" to enable the function. 2. Currrently, ISDN call information may send syslog's message to host. Other message will be added in the next version. [RADIUS] 1. Added RADIUS client function. Setting is in ">Advanced Setup>RADIUS Setup" of web configurator. [DDNS] 1. Improved DDNS function. [Web Configurator] 1. Improved HTTP daemon to speed the internal file searching. 2. Moved "Syslog Setup" from "System Management>Diagnostic Tools" to "System Management". 3. Added "RADIUS Setup" in "Advanced Setup". 4. Added "Configuration Backup / Restoration" in "System Management". [Telnet] 1. Fixed the crash problem that diaplaying the "Online status" page with a 10 second refresh rate and running "ip ping xx.xx.xx.xx" in Telnet connection produce the router to reboot. [DNS] 1. Fixed the problem that the Secondary IP address of DNS server does not be used if Primary IP address does not response the DNS request or is wrong address. [Others] 1. Network Neighborhood in PC ( Third-party application in Mac ) can work pass-thru NAT while a host dial-in via ISDN. 2. Fixed the problem that idle time-out function does not work properly with ISDN connection. *********************************************************************************************** *********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v1.08d Build Date/Time : Wed Dec 5 12:56:53.1 2001 DrayTek Corp. Date: 2001/12/05 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00108.all --- Lastest released firmware (v2k00108.bin + v2k00108.web) \Firmware\v2k00108.rst --- Lastest released firmware (v2k00108.cfg + v2k00108.bin + v2k00108.web) \Firmware\v2k00108.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00108.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00108.web --- The ROM file of webpages of Web Configurator << Tools >>> \Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c firmware or laster. \Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000 \Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95 \Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98 Hint for upgrading Firmware: 1. The file v2k00108.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you could upgrade v2k00108.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Support Models: Vigor2000 Release Notes: 1. [Web Configurator] a. Fixed IE6.0 layout problem. *********************************************************************************************** *********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v1.08 Build Date/Time : Fri Oct 19 16:0:13.54 2001 DrayTek Corp. Date: 2001/10/25 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00108.all --- Lastest released firmware (v2k00108.bin + v2k00108.web) \Firmware\v2k00108.rst --- Lastest released firmware (v2k00108.cfg + v2k00108.bin + v2k00108.web) \Firmware\v2k00108.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00108.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00108.web --- The ROM file of webpages of Web Configurator << Tools >>> \Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c firmware or laster. \Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000 \Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95 \Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98 Hint for upgrading Firmware: 1. The file v2k00108.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you could upgrade v2k00108.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Support Models: Vigor2000 Release Notes: 1. [Web Configurator] a. Added "Clear" and "Clear All" buttons for DDNS, Open Ports and Call Schedule Profiles. b. Improved HTTP daemon against attacks by nimda virus. c. Removed "None" option of "Link Type" for "Dialing to a Single ISP" and "Call Control and PPP/MP Setup". d. Added more heximal records for "Diagnostic Tools" > "Triggered Dial-Out Packet Header". e. Fixed a bug that all password fields can not use '*' and '+' character. 2. [PPPoE] Added the DSS over PPPoE function for PPPoE-enabled ADSL access. Note: DSS stands for Dynamic Service Selection. If the PPPoE-enabled ADSL access netowrk supports multiple PPPoE servers for differnet service grade, the function can automatically connect your router to correct PPPoE server. 3. [NAT] Fixed a Port Redirection problem. 4. [ISDN dial-backup] Improved the stability of ISDN dial-backup function. 5. [DDNS] Improved DDNS function. If you have any DDNS update problem, you can use telnet command "ddns log" to get logs. *********************************************************************************************** *********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v1.07c Build Date/Time : Fri Sep 7 17:34:49.38 2001 DrayTek Corp. Date: 2001/09/07 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00107.all --- Lastest released firmware (v2k00107.bin + v2k00107.web) \Firmware\v2k00107.rst --- Lastest released firmware (v2k00107.cfg + v2k00107.bin + v2k00107.web) \Firmware\v2k00107.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00107.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00107.web --- The ROM file of webpages of Web Configurator << Tools >>> \Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c firmware. \Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000 \Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95 \Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98 Hint for upgrading Firmware: 1. The file v2k00107.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you could upgrade v2k00107.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Support Models: Vigor2000 Release Notes: 1. [Router Tools and Virtual TA Client] After v1.07 firmware, you should use new Router Tools 2.01 version. 2. [PPP-over-V.110] Add PPPoV110 indication on the "Online Status" page. 3. [Always-On for PPPoE/PPTP] Add an "Always-On" setting for PPPoE/PPTP dial-up connection. 4. [Disable PING from the Internet] Add a checkbox under Management Setup to enable/disable PING packets from the Internet. 5. [Call Scheduler] Change the default settings of schedules to be 2000/01/01. 6. [RIP control for LAN] Add a RIP control for LAN interface under "LAN TCP/IP and DHCP Setup" page. If your local networks has many subnets want to share the router to the Internet. Please set "RIP Protocol Control" to be "1st subnet". 7. [DNS Proxy] Improve DNS Proxy for working with RedHat 7.1 Linux. 8. [DHCP Server] Add a Gateway IP Address setting for DHCP server on Web Configurator. *********************************************************************************************** *********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v1.07 Build Date/Time : Fri Jun 22 11:49:27.86 2001 DrayTek Corp. Date: 2001/06/22 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00107.all --- Lastest released firmware (v2k00106.bin + v2k00106.web) \Firmware\v2k00107.rst --- Lastest released firmware (v2k00106.cfg + v2k00106.bin + v2k00106.web) \Firmware\v2k00107.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00107.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00107.web --- The ROM file of webpages of Web Configurator << Tools >>> \Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07 firmware. \Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000 \Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95 \Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98 Hint for upgrading Firmware: 1. The file v2k00107.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you could upgrade v2k00107.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Release Notes: 1. [Router Tools and Virtual TA Client] The Router Tools and Virtual TA Client have been updated, you have to uninstall them from your computer first, then install new ones. You will get new release in the Tools folder. a. The system administrator password has been encrypted between router and Smart Start Wizard. b. Fixed a dual-CPUs problem for Virtual TA Clients. 2. [ISDN interface control] Add a ISDN interface control option on Web Configurator to enable or disable ISDN port. You will find the option in "ISDN Setup" of Basic Setup group. 3. [PPP-over-V.110] Support PPP over V.110 protocol for GSM mobile users remote dial-in access. 4. [MTU setting for WAN] Add a Telnet command "wan mtu ..." to set the MTU (Maximum Transmission Unit) for the Ethernet WAN interface. You can use this command to configure the MTU size for ISDN, PPPoE, PPTP and Static IP modes. 5. [SNMP Agent] Support SNMP (Simple Network Management Protocol) for improving the capabilities of network management. You will find SNMP Setup in the "Management Setup" of System Management group. 6. [DDNS function] Support DDNS (Dynamic Domain Name System) function. If you are a registered user of www.dyndns.org (the provider of DDNS), you can give one or many domain names for your active WAN interface using the function. 7. [Time Client and Call Scheduler] Support NTP (Network Time Procotol) client and Call Scheduler function. The Call Scheduler funtion provides you to schedule router's WAN connection or LAN-to-LAN connection by your local time. The NTP client setup could be found in "Time Setup" of System Management group. The profiles of Call Scheduler could be found in "Call Scheduler Setup" of Advanced Setup group. Also you will see these profiles could be assigned for Interface Access (ISDN, PPPoE and PPTP) and LAN-to-LAN access. 8. [Online Status] Add a System Uptime on the "Online Status" page of web configurator. 9. [DHCP Server] If put zero in the IP Pool Counts, the dynamic IP pool will be disabled. Now you can use Telnet command set "srv dhcp fixip" to add or delete static IP pool. This static IP pool supports 10 IP addresses. > srv dhcp fixip ? % Valid subcommands are: add clr del Under the "srv dhcp fixip" command string, it support three subcommands: "add", "clr" and "del". > srv dhcp fixip add ? % srv dhcp fixip add The "add" subcommand can add a specific IP address based on host's Ethernet MAC address. The Host ID is optional. For example, if you want to specify a IP address 192.168.1.123 to a specific computer with MAC address 00-50-7F-12-34-56, you can try the following command to add. > srv dhcp fixip add 192.168.1.123 00-50-7F-12-34-56 vigor > srv dhcp fixip del ? % srv dhcp fixip del The "del" subcommand can delete a pre-assigned IP address from the static IP pool. For example, > srv dhcp fixip del 192.168.1.123 the host 192.168.1.123 will be removed from the static IP pool. > srv dhcp fixip clr The "clr" subcommand can clear the static IP pool to default values. 10. [Verify default Settings] A new Telnet command "sys cfg status" can check if the router is working with default settings. If yes, you will see the following message. > sys cfg status Profile version: 0x2 Status: 0 (0x293ab002) where Status: 0 (0x293ab002) means the router is default settings. *********************************************************************************************** *********************************************************************************************** Release Notes for Vigor2000 Firmware Version : v1.06b Build Date/Time : Thu Feb 15 16:36:46.39 2001 DrayTek Corp. Date: 2001/02/16 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00106.all --- Lastest released firmware (v2k00106.bin + v2k00106.web) \Firmware\v2k00106.rst --- Lastest released firmware (v2k00106.cfg + v2k00106.bin + v2k00106.web) \Firmware\v2k00106.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00106.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator Hint for upgrading Firmware: 1. The file v2k00106.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you should upgrade v2k00106.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Release Note: 1. Fixed a Typing error in ipnatdmz.sht of Web Configurator. "Corbg." ---> "Corp." 2. ISDN dial-in improvement. Sometimes the dial-in will be failed when the remote ISDN TA or router to use ML-PPP to dial into Vigor2000. 3. Fix a problem that Open Ports can not input 65535 port number. 4. Fix a Clear button problem under "Advanced Setup" > "IP Filter/Firewall Setup" > "Edit Filter Set". *********************************************************************************************** *********************************************************************************************** Release Note for Vigor2000 Firmware Version : v1.06a Build Date/Time : Thu Jan 11 16:52:37.15 2001 DrayTek Corp. Date: 2001/01/12 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00106.all --- Lastest released firmware (v2k00106.bin + v2k00106.web) \Firmware\v2k00106.rst --- Lastest released firmware (v2k00106.cfg + v2k00106.bin + v2k00106.web) \Firmware\v2k00106.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00106.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator \Firmware\v2kfm106a.zip --- Compressed all files <<< Router Tools & Virtual TA Client >>> \Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms \Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000 \Tools\Windows\VSetup95.exe --- VTA client for Windows 95 \Tools\Windows\VSetup98.exe --- VTA client for Windows 98 \Tools\Mac OS\Vigor2000 Tools Installer.hqx --- Vigor2000 Tools for Mac OS Hint for upgrading Firmware: 1. The file v2k00106.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you should upgrade v2k00106.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Release Note: 1. Improve DMZ host function for Mac OS 9. 2. Add Open Ports function which allow users to open a port range for specific network applications. 3. Improve NAT engine for FTP protocol pass-thru. 4. Fix a LAN-to-LAN and ISP access via ISDN simultaneouly problem which when a LAN-to-LAN connection is up the ISP access will be failed. 5. Improve Web Configurator for more user-friendly with JavaScripts. 6. Improve Web Configurator for IE 5.5 and Netscape 6.0 browser. 7. IPSec ESP tunnel mode pass-thru support. *********************************************************************************************** *********************************************************************************************** Release Note for Vigor2000 Firmware Version : v1.06 Build Date/Time : Thu Nov 2 16:10:53.64 2000 DrayTek Corp. Date: 2000/11/02 *********************************************************************************************** Files Description: <<< Firmware >>> \Firmware\v2k00106.all --- Lastest released firmware (v2k00106.bin + v2k00106.web) \Firmware\v2k00106.rst --- Lastest released firmware (v2k00106.cfg + v2k00106.bin + v2k00106.web) \Firmware\v2k00106.bin --- Lastest released firmware (router program firmware only) \Firmware\v2k00106.cfg --- The ROM file of factory default settings excluding Lan2Lan and IP Filter \Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator \Firmware\v2kfm106.zip --- Compressed all files <<< Router Tools & Virtual TA Client >>> \Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms \Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000 \Tools\Windows\VSetup95.exe --- VTA client for Windows 95 \Tools\Windows\VSetup98.exe --- VTA client for Windows 98 \Tools\Mac OS\Vigor2000 Tools Installer.hqx --- Vigor2000 Tools for Mac OS Hint for upgrading Firmware: 1. The file v2k00106.all should be upgraded under the boot loader mode. Please use console port (RS-232 with 115200 8n1) to force the router enter boot loader mode. 2. If you don't care the current settings in your Vigor2000 or you want to reset the router, you should upgrade v2k00106.rst to resotore settings to be default values. We recommended you upgrade this file, if your router firmware version is older than v1.03. 3. If you can't connect to console port to force router enter boot loader mode to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator to upgrade *.bin first and then *.web. Note that you have to wait for 10 seconds between two upgrading procedures. Finishing all upgrade, please power off-on again. Release Note: 1. PPTP client for few specific PPTP-enabled ADSL modem To click "Quick Setup" > "Internet Access Setup" > "PPTP" configures PPTP and also can configure the ISDN dial backup settings. Note: Before you enable the PPTP client, you should use 2nd IP address to connect to the ADSL modem. Please click "Basic Setup" > "Ethernet TCP/IP and DHCP Setup" to enable the 2nd IP address and assign the IP address and subnet mask. 2. Netmeeting support The Netmeeting support is just a beta release. Based on the current release, you just can make a Netmeeting call directly using peer IP address. If you want to peer to call into your local Netmeeting software, please add two port redirection entries in the "Advanced Setup" > "NAT Setup" > "Configure Port Redirection Table". These additional ports is TCP/1720 and TCP/1503. However, the ILS server support should be released in the next version. 3. PPTP Tunnel Passthru This version supports any of PPTP clients could create a tunnel through the router to establish a secure channel with outside PPTP server. 4. PPPoE Enhancement This version has done some significant performance improvement for T-DSL services in Germany. If you are a T-DSL user, please use the version. 5. Tools for Windows Platform Now, the Windows utility has been separate to two independent installers, one is named "Router Tools" including "Firmware Upgrade Utility" and "Smart Start Wizard", the other is named "Virtual TA" client driver which has been supported for Win95 OSR2.1, Win98 and Win2000. The Router Tools can support whole Windows platforms. 6. LAN-to-LAN Profile bug Fixed a bug which the LAN-to-LAN profile settings will be clear to be default value after upgrade new firmware. 7. Call Control Parameters Please click "Advanced Setup" > "Call Control and PPP/MP Setup", you will see the following two parameters: Dial Retry and Dial Delay Interval. These are globally settings for all dial-out mechanism, such as ISDN dialup, PPPoE or PPTP for ADSL access. The Dial Retry means the router will dial the preset times per outgoing packet. The Dial Delay Interval means the time interval between two re-dials. 8. Remote Activation Function Please click "Advanced Setup" > "Call Control and PPP/MP Setup", you will see the "Remote Activation" field. You should specify the caller phone number here. Once the router receives a call from the specified phone or ISDN line number, it is will drop the incoming call immediatelly and then dial to the ISP for the Internet access. If you are a fixed IP user, the router will be wake up remotely, then you could access to your local network resource very easy. Note: Before you enable the function, you should set a ISP access profile following the links "Quick Setup" > "Internet Access Setup" > "Dialling to Single ISP". 9. Remote Management Add a "Allowing management from the Internet" checkbox on the Management Setup page of Web Configurator. By default, the checkbox is unchecked. It means the router can NOT configure from the Internet. *********************************************************************************************** [End of File]